Summary of LG Dryer Error Codes
CodeMeaning
d80 / d90 / d95 / d75Exhaust restriction — Flow Sense has detected the vent is about 75%, 80%, 90% or 95% blocked.
tE1 / tE2 / tE3Thermistor error — a temperature sensor reading is out of range. tE2 typically appears in cold conditions or during steam cycles.
nPNo power at the heater — the dryer isn't detecting current at the heating element.
PSPower supply wiring error — improper voltage in the power cord.
dEDoor error — the door isn't fully closed.
HSHumidity sensor error — cycles may run up to about 2.5 hours.
GASGas models — the dryer isn't receiving gas.
PFPower failure — the cycle was interrupted by a power outage.

d80 / d90 / d95 / d75 — Exhaust restriction

Exhaust restriction — Flow Sense has detected the vent is about 75%, 80%, 90% or 95% blocked.

Common causes

  • Lint build-up in the vent duct
  • Crushed or kinked vent hose behind the dryer
  • Vent run too long or with too many bends
  • Blocked outside vent hood

Try this first

  • Clean the lint filter
  • Pull the dryer out and straighten or replace a crushed vent hose
  • Check the outside vent flap opens freely

When to call: The dryer will still run, but drying takes longer and parts run hot. Long condo vent runs often need a professional cleaning.

tE1 / tE2 / tE3 — Thermistor error

Thermistor error — a temperature sensor reading is out of range. tE2 typically appears in cold conditions or during steam cycles.

Common causes

  • Failed thermistor
  • Loose sensor wiring
  • For tE2, cold air or extra moisture cooling the duct

Try this first

  • Unplug, hold Start/Pause for 5 seconds and restore power
  • For tE2, clean the lint filter and check the vent

When to call: If tE1 or tE3 keeps returning, the thermistor or its wiring needs to be tested and replaced.

nP — No power at the heater

No power at the heater — the dryer isn't detecting current at the heating element.

Common causes

  • A tripped half of the 240V breaker
  • Loose power cord connection
  • Outlet or household wiring problem

Try this first

  • Reset the dryer breaker (off for at least 10 seconds, then on)
  • Make sure the power cord is fully plugged in

When to call: If resetting the breaker doesn't fix it, the outlet or wiring needs a licensed electrician; if the power checks out, we'll test the dryer side.

PS — Power supply wiring error

Power supply wiring error — improper voltage in the power cord.

Common causes

  • Power cord wires reversed at the dryer's terminal block (often after a new cord install)
  • Outlet wiring problem

Try this first

  • None — switch off the breaker and don't use the dryer until the wiring is checked

When to call: Miswired cords are a safety hazard. Have the cord connection and outlet checked before running the dryer again.

dE — Door error

Door error — the door isn't fully closed.

Common causes

  • Clothing caught in the door
  • Lint filter not seated properly
  • Damaged door or door switch

Try this first

  • Reseat the lint filter
  • Clear the door opening and close the door firmly

When to call: A failed door switch is a quick, inexpensive repair.

HS — Humidity sensor error

Humidity sensor error — cycles may run up to about 2.5 hours.

Common causes

  • Dryer-sheet or fabric-softener residue on the sensor bars
  • Failed sensor or wiring

Try this first

  • Wipe the metal sensor bars below the lint filter with a damp cloth and let them dry

When to call: If clean sensor bars don't fix it, the sensor circuit needs testing.

GAS — Gas models

Gas models — the dryer isn't receiving gas.

Common causes

  • Gas shut-off valve closed
  • Kinked gas supply line
  • Gas service interrupted

Try this first

  • Make sure the gas valve behind the dryer is fully open and the line isn't kinked

When to call: If you ever smell gas, don't run the dryer or operate switches — leave the house and call your gas utility from outside.

PF — Power failure

Power failure — the cycle was interrupted by a power outage.

Common causes

  • Outage or brief power interruption (common during Florida summer storms)

Try this first

  • Unplug the dryer, hold Start/Pause for 5 seconds, plug it back in and restart the cycle

When to call: No service needed unless PF appears without any power interruption.

How to reset

LG's reset: unplug the dryer, press and hold Start/Pause for 5 seconds, then plug it back in and try again. If the code returns, the cause is still there.

Codes vary by model and year. Check your owner's manual for your exact model — if a code isn't listed here, call us and we'll look it up.

Still stuck? We repair LG dryers across Clearwater and all of Pinellas County — see LG repair.

Last reviewed 2026-10-07 by Mako Appliance Repair.

Code won't clear? We'll fix it.

$79 diagnostic credited to your repair · 45-day parts & labor warranty · Open 7 days · 7:30am–8:30pm

Call nowBook online